Abstract: Formaldehyde as an indoor pollutant is harmful to human health even with a very low content in the atmosphere. It can be removed through catalytic oxidation, and Pt/TiO2 proved to be a potential catalyst and can be operated at low temperature and high space velocity. To understand the mechanism of catalytic oxidation of formaldehyde over Pt/TiO2, the intrinsic kinetics of reaction was investigated in a fixed-bed plug flow differential reactor at atmospheric pressure. A power law rate equation was established as r=1.87×107 exp(-47.50×103/(R×T))×c1.27HCHO, which gave a good correlation to the experimental results.
-
Key words:
- formaldehyde /
- catalytic oxidation /
- differential reactor /
- intrinsic kinetics
点击查看大图
计量
- 文章访问数: 1706
- HTML全文浏览量: 32
- PDF下载量: 1128
- 被引次数: 0